{"id":11289,"date":"2024-10-11T13:22:22","date_gmt":"2024-10-11T13:22:22","guid":{"rendered":"https:\/\/prod.zbt.compositas.io\/?page_id=11289"},"modified":"2026-10-01T13:24:29","modified_gmt":"2026-10-01T13:24:29","slug":"hy-lab-laboratory-for-hydrogen-quality","status":"publish","type":"page","link":"https:\/\/zbt.de\/en\/institute\/facilities\/hy-lab-laboratory-for-hydrogen-quality\/","title":{"rendered":"Hy-Lab \u2013 Laboratory for hydrogen quality"},"content":{"rendered":"<section class=\"intro\">\n    <figure class=\"intro__figure\">\n                              <img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"1678\" src=\"https:\/\/zbt.de\/app\/uploads\/2024\/09\/zbt-labor-hylab-wasserstoff-qualitaet-fisheye-scaled.jpg\" class=\"intro__image\" alt=\"A view inside the Hy-Lab hydrogen quality laboratory at the ZBT, with numerous analytical instruments on the tables\" srcset=\"https:\/\/zbt.de\/app\/uploads\/2024\/09\/zbt-labor-hylab-wasserstoff-qualitaet-fisheye-scaled.jpg 2560w, https:\/\/zbt.de\/app\/uploads\/2024\/09\/zbt-labor-hylab-wasserstoff-qualitaet-fisheye-300x197.jpg 300w, https:\/\/zbt.de\/app\/uploads\/2024\/09\/zbt-labor-hylab-wasserstoff-qualitaet-fisheye-1024x671.jpg 1024w, https:\/\/zbt.de\/app\/uploads\/2024\/09\/zbt-labor-hylab-wasserstoff-qualitaet-fisheye-768x503.jpg 768w, https:\/\/zbt.de\/app\/uploads\/2024\/09\/zbt-labor-hylab-wasserstoff-qualitaet-fisheye-1536x1007.jpg 1536w, https:\/\/zbt.de\/app\/uploads\/2024\/09\/zbt-labor-hylab-wasserstoff-qualitaet-fisheye-2048x1342.jpg 2048w, https:\/\/zbt.de\/app\/uploads\/2024\/09\/zbt-labor-hylab-wasserstoff-qualitaet-fisheye-1320x865.jpg 1320w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/>\n        <div class=\"intro__overlay intro__overlay--transparent\">\n                    <\/div>\n            <\/figure>\n    <div class=\"intro__content\">\n        <h1 class=\"intro__heading\">Hy-Lab \u2013 Laboratory for hydrogen quality<\/h1>\n        <h4 class=\"intro__subheading\">Reliable hydrogen analysis in accordance with international standards<\/h4>\n        <div class=\"intro__text\"><p>ZBT operates one of the few independent laboratories in Europe capable of precisely analysing hydrogen in accordance with EN 17124 and ISO 14687. Building on over 15 years of experience in gas analytics, we develop and validate highly specialised methods for measuring even the smallest impurities in the ppb range &#8211; for gas stations, supply chains, and research projects. <\/p>\n<\/div>\n            <\/div>\n<\/section>\n<section class=\"teaser-grid teaser-grid--white\"\n    dir=\"ltr\">\n    <div class=\"teaser-grid__content\" dir=\"ltr\">\n        <h2 class=\"teaser-grid__heading\">Technology and Features<\/h2>\n        <div class=\"teaser-grid__text\"><div id=\"c3690\" class=\"csc-default\">\n<p class=\"\" data-start=\"257\" data-end=\"636\">The H\u2082 quality laboratory is equipped with state-of-the-art systems for precise analysis and sampling, including gas-dilution-based calibration units with mass flow controllers, a CE-certified <strong>Hy-SaM system<\/strong> for sampling at 70 MPa and 35 MPa fueling stations, as well as four integrated test benches for fuel cell impurity analysis and material testing. The infrastructure is supplemented by high-performance online and offline measurement technology for quantifying even the smallest impurities in the ppb range. <\/p>\n<\/div>\n<\/div>\n    <\/div>\n    <figure class=\"teaser-grid__figure\" dir=\"ltr\">\n                                <img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"1441\" src=\"https:\/\/zbt.de\/app\/uploads\/2026\/08\/20260728_0924230-scaled.jpg\" class=\"teaser-grid__image\" alt=\"\" srcset=\"https:\/\/zbt.de\/app\/uploads\/2026\/08\/20260728_0924230-scaled.jpg 2560w, https:\/\/zbt.de\/app\/uploads\/2026\/08\/20260728_0924230-300x169.jpg 300w, https:\/\/zbt.de\/app\/uploads\/2026\/08\/20260728_0924230-1024x577.jpg 1024w, https:\/\/zbt.de\/app\/uploads\/2026\/08\/20260728_0924230-768x432.jpg 768w, https:\/\/zbt.de\/app\/uploads\/2026\/08\/20260728_0924230-1536x865.jpg 1536w, https:\/\/zbt.de\/app\/uploads\/2026\/08\/20260728_0924230-2048x1153.jpg 2048w, https:\/\/zbt.de\/app\/uploads\/2026\/08\/20260728_0924230-1320x743.jpg 1320w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/>\n        <div class=\"flex teaser-grid__overlay teaser-grid__overlay--transparent\">\n                    <\/div>\n            <\/figure>\n<\/section>\n<section class=\"teaser-grid teaser-grid--white\"\n    dir=\"rtl\">\n    <div class=\"teaser-grid__content\" dir=\"ltr\">\n        <h2 class=\"teaser-grid__heading\">Services<\/h2>\n        <div class=\"teaser-grid__text\"><ul>\n<li class=\"\" data-start=\"173\" data-end=\"215\">\n<p class=\"\" data-start=\"175\" data-end=\"215\">Hydrogen Analysis in Accordance with EN 17124:2022<\/p>\n<\/li>\n<li class=\"\" data-start=\"216\" data-end=\"304\">\n<p class=\"\" data-start=\"218\" data-end=\"304\">Hydrogen sampling at refueling stations (70 MPa and 35 MPa) and along the supply chain<\/p>\n<\/li>\n<li class=\"\" data-start=\"305\" data-end=\"378\">\n<p class=\"\" data-start=\"307\" data-end=\"378\">Analysis of sulfur compounds, natural gas, ammonia, and other gases<\/p>\n<\/li>\n<li class=\"\" data-start=\"379\" data-end=\"456\">\n<p class=\"\" data-start=\"381\" data-end=\"456\">Development, Validation, and Testing of Methods for Analysis and Sampling<\/p>\n<\/li>\n<li class=\"\" data-start=\"457\" data-end=\"532\">\n<p class=\"\" data-start=\"459\" data-end=\"532\">Use and Evaluation of Online Sensing and Gas Purification Technologies<\/p>\n<\/li>\n<li class=\"\" data-start=\"533\" data-end=\"617\">\n<p class=\"\" data-start=\"535\" data-end=\"617\">Investigation of Contaminants in Fuel Cells and Material Qualification<\/p>\n<\/li>\n<\/ul>\n<\/div>\n    <\/div>\n    <figure class=\"teaser-grid__figure\" dir=\"ltr\">\n                                <img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"2560\" src=\"https:\/\/zbt.de\/app\/uploads\/2024\/09\/DSC_5833-scaled.jpg\" class=\"teaser-grid__image\" alt=\"Test benches, laboratory, Christian He\u00dfke\" srcset=\"https:\/\/zbt.de\/app\/uploads\/2024\/09\/DSC_5833-scaled.jpg 2560w, https:\/\/zbt.de\/app\/uploads\/2024\/09\/DSC_5833-300x300.jpg 300w, https:\/\/zbt.de\/app\/uploads\/2024\/09\/DSC_5833-1024x1024.jpg 1024w, https:\/\/zbt.de\/app\/uploads\/2024\/09\/DSC_5833-150x150.jpg 150w, https:\/\/zbt.de\/app\/uploads\/2024\/09\/DSC_5833-768x768.jpg 768w, https:\/\/zbt.de\/app\/uploads\/2024\/09\/DSC_5833-1536x1536.jpg 1536w, https:\/\/zbt.de\/app\/uploads\/2024\/09\/DSC_5833-2048x2048.jpg 2048w, https:\/\/zbt.de\/app\/uploads\/2024\/09\/DSC_5833-1320x1320.jpg 1320w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/>\n        <div class=\"flex teaser-grid__overlay teaser-grid__overlay--blue\">\n                    <\/div>\n            <\/figure>\n<\/section>\n<section class=\"teaser-grid teaser-grid--white\"\n    dir=\"ltr\">\n    <div class=\"teaser-grid__content\" dir=\"ltr\">\n        <h2 class=\"teaser-grid__heading\">Analytical Methods and Detection Limits<\/h2>\n        <div class=\"teaser-grid__text\"><table class=\"contenttable\" border=\"1\" width=\"454\" cellspacing=\"0\" cellpadding=\"0\"><span data-mce-type=\"bookmark\" style=\"display: inline-block; width: 0px; overflow: hidden; line-height: 0;\" class=\"mce_SELRES_start\"><\/span><\/p>\n<tbody>\n<tr>\n<td width=\"138\">Impurity<\/td>\n<td width=\"117\">ISO 14687:2019<br \/>\nEN 17124:2022<br \/>\n[\u00b5mol\/mol]<\/td>\n<td width=\"113\">Analytical Method<\/td>\n<td width=\"85\">Limit of Quantification (LoQ)<br \/>\n[\u00b5mol\/mol]<\/td>\n<\/tr>\n<tr>\n<td width=\"138\">Water<\/td>\n<td width=\"117\">5<\/td>\n<td width=\"113\">QCM<\/td>\n<td width=\"85\">0.5<\/td>\n<\/tr>\n<tr>\n<td width=\"138\">Total Hydrocarbons<\/td>\n<td width=\"117\">2<\/td>\n<td width=\"113\">GC-PED<\/td>\n<td width=\"85\">0.5<\/td>\n<\/tr>\n<tr>\n<td width=\"138\">Methane<\/td>\n<td width=\"117\">100<\/td>\n<td width=\"113\">GC-PED<\/td>\n<td width=\"85\">0.5<\/td>\n<\/tr>\n<tr>\n<td width=\"138\">Oxygen<\/td>\n<td width=\"117\">5<\/td>\n<td width=\"113\">GC-PED<\/td>\n<td width=\"85\">1.25<\/td>\n<\/tr>\n<tr>\n<td width=\"138\">Helium<\/td>\n<td width=\"117\">300<\/td>\n<td width=\"113\">EI-MS<\/td>\n<td width=\"85\">75<\/td>\n<\/tr>\n<tr>\n<td width=\"138\">Argon<\/td>\n<td width=\"117\">300<\/td>\n<td width=\"113\">GC-PED<\/td>\n<td width=\"85\">75<\/td>\n<\/tr>\n<tr>\n<td width=\"138\">Nitrogen<\/td>\n<td width=\"117\">300<\/td>\n<td width=\"113\">GC-PED<\/td>\n<td width=\"85\">75<\/td>\n<\/tr>\n<tr>\n<td width=\"138\">Carbon Dioxide<\/td>\n<td width=\"117\">2<\/td>\n<td width=\"113\">IMR-MS<\/td>\n<td width=\"85\">0.5<\/td>\n<\/tr>\n<tr>\n<td width=\"138\">Carbon Monoxide<\/td>\n<td width=\"117\">0.2<\/td>\n<td width=\"113\">GC-PED<\/td>\n<td width=\"85\">0.05<\/td>\n<\/tr>\n<tr>\n<td width=\"138\">Total sulfur compounds<\/td>\n<td width=\"117\">0.004<\/td>\n<td width=\"113\">TD-GC-SCD<\/td>\n<td width=\"85\">0.001<\/td>\n<\/tr>\n<tr>\n<td width=\"138\">Formaldehyde<\/td>\n<td width=\"117\">0.2<\/td>\n<td width=\"113\">IMR-MS<\/td>\n<td width=\"85\">0.05<\/td>\n<\/tr>\n<tr>\n<td width=\"138\">Formic Acid<\/td>\n<td width=\"117\">0.2<\/td>\n<td width=\"113\">IMR-MS<\/td>\n<td width=\"85\">0.05<\/td>\n<\/tr>\n<tr>\n<td width=\"138\">Ammonia<\/td>\n<td width=\"117\">0.1<\/td>\n<td width=\"113\">IMR-MS<\/td>\n<td width=\"85\">0.025<\/td>\n<\/tr>\n<tr>\n<td width=\"138\">Halogenated compounds<\/td>\n<td width=\"117\">0.05<\/td>\n<td width=\"113\">IMR-MS<\/td>\n<td width=\"85\">0.0125<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n    <\/div>\n    <figure class=\"teaser-grid__figure\" dir=\"ltr\">\n                                <img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"1709\" src=\"https:\/\/zbt.de\/app\/uploads\/2026\/07\/DSC_6759-scaled.jpg\" class=\"teaser-grid__image\" alt=\"\" srcset=\"https:\/\/zbt.de\/app\/uploads\/2026\/07\/DSC_6759-scaled.jpg 2560w, https:\/\/zbt.de\/app\/uploads\/2026\/07\/DSC_6759-300x200.jpg 300w, https:\/\/zbt.de\/app\/uploads\/2026\/07\/DSC_6759-1024x684.jpg 1024w, https:\/\/zbt.de\/app\/uploads\/2026\/07\/DSC_6759-768x513.jpg 768w, https:\/\/zbt.de\/app\/uploads\/2026\/07\/DSC_6759-1536x1025.jpg 1536w, https:\/\/zbt.de\/app\/uploads\/2026\/07\/DSC_6759-2048x1367.jpg 2048w, https:\/\/zbt.de\/app\/uploads\/2026\/07\/DSC_6759-1320x881.jpg 1320w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/>\n        <div class=\"flex teaser-grid__overlay teaser-grid__overlay--blue\">\n                    <\/div>\n            <\/figure>\n<\/section>\n<section class=\"teaser-grid teaser-grid--white\"\n    dir=\"rtl\">\n    <div class=\"teaser-grid__content\" dir=\"ltr\">\n        <h2 class=\"teaser-grid__heading\">Hy-SaM \u2013 Sampling at Hydrogen Refueling Stations<\/h2>\n        <div class=\"teaser-grid__text\"><p data-start=\"178\" data-end=\"418\">With Hy-SaM, the ZBT has a CE-certified <strong>system for sampling at hydrogen refueling stations<\/strong> in accordance with ISO 19880-1 and SAE J2601 &#8211; without interfering with the refueling protocol and without electronic interfaces. <\/p>\n<p><\/br>This robust system enables <strong>simultaneous sampling<\/strong> with up to three cylinders (2.25 L or 10 L), even in combination with particulate sampling. Hy-SaM is used in national and European projects, as well as in collaboration with CEP and H2-Mobility, and has proven itself in numerous campaigns at actual gas stations. <\/p>\n<\/div>\n    <\/div>\n    <figure class=\"teaser-grid__figure\" dir=\"ltr\">\n                                <img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"1709\" src=\"https:\/\/zbt.de\/app\/uploads\/2026\/08\/DSC_6773-scaled.jpg\" class=\"teaser-grid__image\" alt=\"\" srcset=\"https:\/\/zbt.de\/app\/uploads\/2026\/08\/DSC_6773-scaled.jpg 2560w, https:\/\/zbt.de\/app\/uploads\/2026\/08\/DSC_6773-300x200.jpg 300w, https:\/\/zbt.de\/app\/uploads\/2026\/08\/DSC_6773-1024x684.jpg 1024w, https:\/\/zbt.de\/app\/uploads\/2026\/08\/DSC_6773-768x513.jpg 768w, https:\/\/zbt.de\/app\/uploads\/2026\/08\/DSC_6773-1536x1025.jpg 1536w, https:\/\/zbt.de\/app\/uploads\/2026\/08\/DSC_6773-2048x1367.jpg 2048w, https:\/\/zbt.de\/app\/uploads\/2026\/08\/DSC_6773-1320x881.jpg 1320w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/>\n        <div class=\"flex teaser-grid__overlay teaser-grid__overlay--transparent\">\n                    <\/div>\n            <\/figure>\n<\/section>\n<section class=\"teaser-grid teaser-grid--white\"\n    dir=\"ltr\">\n    <div class=\"teaser-grid__content\" dir=\"ltr\">\n        <h2 class=\"teaser-grid__heading\">Research &#038; Networks<\/h2>\n        <div class=\"teaser-grid__text\"><p class=\"\" data-start=\"179\" data-end=\"767\">As a European reference laboratory for hydrogen quality, the ZBT is involved in numerous research projects and partnerships. In the EU project <strong data-start=\"326\" data-end=\"338\">Hydraite<\/strong>, the H\u2082 quality laboratory was established as a European quality laboratory. In <strong data-start=\"413\" data-end=\"427\">MetroHyVe2<\/strong> and <strong data-start=\"432\" data-end=\"447\">MetHyTrucks<\/strong>, the ZBT contributes its expertise to the further development of analysis, sampling, and online measurement methods.    <\/p>\n<p><\/br>In addition, the laboratory works closely with the <strong data-start=\"603\" data-end=\"637\">Clean Energy Partnership (CEP)<\/strong> and <strong data-start=\"642\" data-end=\"669\">H2-Mobility Deutschland<\/strong> and regularly participates in sampling campaigns at gas stations both in Germany and abroad.<\/p>\n<p><\/br><\/p>\n<p class=\"\" data-start=\"769\" data-end=\"980\">Through these activities, the ZBT is strengthening its role in the European hydrogen network and making an important contribution to standardisation and quality assurance along the hydrogen value chain.<\/p>\n<\/div>\n    <\/div>\n    <figure class=\"teaser-grid__figure\" dir=\"ltr\">\n                                <img loading=\"lazy\" decoding=\"async\" width=\"2000\" height=\"1334\" src=\"https:\/\/zbt.de\/app\/uploads\/2024\/08\/zbt-wasserstoff-testfeld-tankstelle-schalttafel-ausschnitt.jpg\" class=\"teaser-grid__image\" alt=\"A side view of a control panel at the ZBT - The Hydrogen and Fuel Cell Center hydrogen test filling station, featuring numerous cables and switches\" srcset=\"https:\/\/zbt.de\/app\/uploads\/2024\/08\/zbt-wasserstoff-testfeld-tankstelle-schalttafel-ausschnitt.jpg 2000w, https:\/\/zbt.de\/app\/uploads\/2024\/08\/zbt-wasserstoff-testfeld-tankstelle-schalttafel-ausschnitt-300x200.jpg 300w, https:\/\/zbt.de\/app\/uploads\/2024\/08\/zbt-wasserstoff-testfeld-tankstelle-schalttafel-ausschnitt-1024x683.jpg 1024w, https:\/\/zbt.de\/app\/uploads\/2024\/08\/zbt-wasserstoff-testfeld-tankstelle-schalttafel-ausschnitt-768x512.jpg 768w, https:\/\/zbt.de\/app\/uploads\/2024\/08\/zbt-wasserstoff-testfeld-tankstelle-schalttafel-ausschnitt-1536x1025.jpg 1536w, https:\/\/zbt.de\/app\/uploads\/2024\/08\/zbt-wasserstoff-testfeld-tankstelle-schalttafel-ausschnitt-1320x880.jpg 1320w\" sizes=\"auto, (max-width: 2000px) 100vw, 2000px\" \/>\n        <div class=\"flex teaser-grid__overlay teaser-grid__overlay--blue\">\n                    <\/div>\n            <\/figure>\n<\/section>\n<div class=\"contact-person contact-person--dark\" dir=\"rtl\">\n        <div class=\"contact-person__content\" dir=\"ltr\">\n            <h3 class=\"contact-person__heading\">Contact<\/h3>\n            <div class=\"contact-person__text\"><p>Group Leader, Gas Analysis | Hy-Lab<\/p>\n<\/div>\n            <div class=\"flex flex-col gap-1\">\n                <div class=\"contact-person__name\">\n                    Matz Dietrich\n                <\/div>\n                            <\/div>\n            <div class=\"flex flex-col gap-2\">\n                <div class=\"flex flex-row items-center gap-2\">\n                    <i><svg class=\"w-4 h-4\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" fill=\"currentColor\" viewBox=\"0 0 512 512\"><path d=\"M375.8 275.2c-16.4-7-35.4-2.4-46.7 11.4l-33.2 40.6c-46-26.7-84.4-65.1-111.1-111.1L225.3 183c13.8-11.3 18.5-30.3 11.4-46.7l-48-112C181.2 6.7 162.3-3.1 143.6 .9l-112 24C13.2 28.8 0 45.1 0 64v0C0 300.7 183.5 494.5 416 510.9c4.5 .3 9.1 .6 13.7 .8c0 0 0 0 0 0c0 0 0 0 .1 0c6.1 .2 12.1 .4 18.3 .4l0 0c18.9 0 35.2-13.2 39.1-31.6l24-112c4-18.7-5.8-37.6-23.4-45.1l-112-48zM447.7 480C218.1 479.8 32 293.7 32 64v0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0c0-3.8 2.6-7 6.3-7.8l112-24c3.7-.8 7.5 1.2 9 4.7l48 112c1.4 3.3 .5 7.1-2.3 9.3l-40.6 33.2c-12.1 9.9-15.3 27.2-7.4 40.8c29.5 50.9 71.9 93.3 122.7 122.7c13.6 7.9 30.9 4.7 40.8-7.4l33.2-40.6c2.3-2.8 6.1-3.7 9.3-2.3l112 48c3.5 1.5 5.5 5.3 4.7 9l-24 112c-.8 3.7-4.1 6.3-7.8 6.3c-.1 0-.2 0-.3 0z\"\/><\/svg><\/i>\n                    <span class=\"contact-person__phone\">+49 203 7598-2464<\/span>\n                <\/div>\n                <div class=\"flex flex-row items-center gap-2\">\n                    <i><svg class=\"w-4 h-4\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" fill=\"currentColor\" viewBox=\"0 0 640 512\"><!--!Font Awesome Pro 6.7.2 by @fontawesome - https:\/\/fontawesome.com License - https:\/\/fontawesome.com\/license (Commercial License) Copyright 2024 Fonticons, Inc.--><path d=\"M96 384l32-16 96-48 160 0 32 0 0-32 0-256 0-32L384 0 32 0 0 0 0 32 0 288l0 32 32 0 32 0 32 0 0 28.2 0 3.8 0 32zm113.7-92.6L128 332.2l0-12.2 0-32-32 0-64 0L32 32l352 0 0 256-160 0-7.6 0-6.8 3.4zM256 448l32 0 128 0 96 48 32 16 0-32 0-3.8 0-28.2 32 0 32 0 32 0 0-32 0-256 0-32-32 0-160 0 0 32 160 0 0 256-64 0-32 0 0 32 0 12.2-81.7-40.8-6.8-3.4-7.6 0-128 0 0-64-32 0 0 64 0 32z\"\/><\/svg><\/i>\n                    <span class=\"contact-person__email\">\n                        <a href=\"mailto:m.dietrich@zbt.de\">m.dietrich@zbt.de<\/a>\n                    <\/span>\n                <\/div>\n            <\/div>\n        <\/div>\n        <figure class=\"contact-person__figure\">\n            <img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"684\" src=\"https:\/\/zbt.de\/app\/uploads\/2024\/10\/DSC_9590-Bearbeitet-2-1024x684.jpg\" class=\"contact-person__image\" alt=\"Matz Dietrich Staff photo\" srcset=\"https:\/\/zbt.de\/app\/uploads\/2024\/10\/DSC_9590-Bearbeitet-2-1024x684.jpg 1024w, https:\/\/zbt.de\/app\/uploads\/2024\/10\/DSC_9590-Bearbeitet-2-300x200.jpg 300w, https:\/\/zbt.de\/app\/uploads\/2024\/10\/DSC_9590-Bearbeitet-2-768x513.jpg 768w, https:\/\/zbt.de\/app\/uploads\/2024\/10\/DSC_9590-Bearbeitet-2-1536x1025.jpg 1536w, https:\/\/zbt.de\/app\/uploads\/2024\/10\/DSC_9590-Bearbeitet-2-2048x1367.jpg 2048w, https:\/\/zbt.de\/app\/uploads\/2024\/10\/DSC_9590-Bearbeitet-2-1320x881.jpg 1320w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/>\n                                    <a href=\"mailto:m.dietrich@zbt.de\" target=\"_self\" class=\"contact-person__link\">\n              <div\n                  class=\"flex contact-person__overlay contact-person__overlay--transparent\">\n                                <\/div>\n            <\/a>\n        <\/figure>\n    <\/div>\n<section class=\"additional-topic additional-topic--light\">\n    <h2 class=\"additional-topic__heading\">Discover more<\/h2>\n    <div class=\"additional-topic__grid\">\n                    <div class=\"additional-topic__item\">\n                <a href=\"https:\/\/zbt.de\/en\/institute\/facilities\/wasserstoff-testfeld\/\" class=\"topic-card\" title=\"Hydrogen test field\">\n    <h4 class=\"topic-card__title\">Hydrogen test field<\/h4>\n    <p class=\"topic-card__text\">The ZBT hydrogen test field is used for testing and further developing hydrogen-related technologies. It houses our hydrogen test filling station and test facilities for hydrogen storage systems, as well as facilities for the production and use of hydrogen derivatives. <\/p>\n    <i class=\"topic-card__arrow\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" fill=\"currentColor\" viewBox=\"0 0 448 512\"><path d=\"M435.3 267.3L446.6 256l-11.3-11.3-168-168L256 65.4 233.4 88l11.3 11.3L385.4 240 16 240 0 240l0 32 16 0 369.4 0L244.7 412.7 233.4 424 256 446.6l11.3-11.3 168-168z\"\/><\/svg><\/i>\n<\/a>\n            <\/div>\n                    <div class=\"additional-topic__item\">\n                <a href=\"https:\/\/zbt.de\/en\/research\/hydrogen\/h2-tankstellentechnologie-legacy\/\" class=\"topic-card\" title=\"H2 refuelling station technology\">\n    <h4 class=\"topic-card__title\">H2 refuelling station technology<\/h4>\n    <p class=\"topic-card__text\">Our hydrogen test refuelling station team focuses on the targeted development and qualification of components and concepts for hydrogen refuelling stations. One focus is on refuelling protocols. <\/p>\n    <i class=\"topic-card__arrow\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" fill=\"currentColor\" viewBox=\"0 0 448 512\"><path d=\"M435.3 267.3L446.6 256l-11.3-11.3-168-168L256 65.4 233.4 88l11.3 11.3L385.4 240 16 240 0 240l0 32 16 0 369.4 0L244.7 412.7 233.4 424 256 446.6l11.3-11.3 168-168z\"\/><\/svg><\/i>\n<\/a>\n            <\/div>\n                    <div class=\"additional-topic__item\">\n                <a href=\"https:\/\/zbt.de\/en\/institute\/departments\/hydrogen-infrastructure\/\" class=\"topic-card\" title=\"Hydrogen Infrastructure\">\n    <h4 class=\"topic-card__title\">Hydrogen Infrastructure<\/h4>\n    <p class=\"topic-card__text\">In the field of hydrogen infrastructure, the ZBT focuses in particular on mobility. The department addresses the entire value chain, from hydrogen production to logistics and distribution to refuelling station technology. <\/p>\n    <i class=\"topic-card__arrow\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" fill=\"currentColor\" viewBox=\"0 0 448 512\"><path d=\"M435.3 267.3L446.6 256l-11.3-11.3-168-168L256 65.4 233.4 88l11.3 11.3L385.4 240 16 240 0 240l0 32 16 0 369.4 0L244.7 412.7 233.4 424 256 446.6l11.3-11.3 168-168z\"\/><\/svg><\/i>\n<\/a>\n            <\/div>\n            <\/div>\n<\/section>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":7,"featured_media":0,"parent":10562,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"class_list":["post-11289","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Hy-Lab \u2013 Laboratory for hydrogen quality - Zentrum f\u00fcr BrennstoffzellenTechnik GmbH<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zbt.de\/en\/institute\/facilities\/hy-lab-laboratory-for-hydrogen-quality\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Hy-Lab \u2013 Laboratory for hydrogen quality - Zentrum f\u00fcr BrennstoffzellenTechnik GmbH\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zbt.de\/en\/institute\/facilities\/hy-lab-laboratory-for-hydrogen-quality\/\" \/>\n<meta property=\"og:site_name\" content=\"Zentrum f\u00fcr BrennstoffzellenTechnik GmbH\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-01T13:24:29+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zbt.de\/en\/institute\/facilities\/hy-lab-laboratory-for-hydrogen-quality\/\",\"url\":\"https:\/\/zbt.de\/en\/institute\/facilities\/hy-lab-laboratory-for-hydrogen-quality\/\",\"name\":\"Hy-Lab \u2013 Laboratory for hydrogen quality - Zentrum f\u00fcr BrennstoffzellenTechnik GmbH\",\"isPartOf\":{\"@id\":\"https:\/\/zbt.de\/#website\"},\"datePublished\":\"2024-10-11T13:22:22+00:00\",\"dateModified\":\"2026-10-01T13:24:29+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/zbt.de\/en\/institute\/facilities\/hy-lab-laboratory-for-hydrogen-quality\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/zbt.de\/en\/institute\/facilities\/hy-lab-laboratory-for-hydrogen-quality\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/zbt.de\/en\/institute\/facilities\/hy-lab-laboratory-for-hydrogen-quality\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/zbt.de\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Institute\",\"item\":\"https:\/\/zbt.de\/en\/institute\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Equipment\",\"item\":\"https:\/\/zbt.de\/en\/institute\/facilities\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Hy-Lab \u2013 Laboratory for hydrogen quality\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/zbt.de\/#website\",\"url\":\"https:\/\/zbt.de\/\",\"name\":\"Zentrum f\u00fcr BrennstoffzellenTechnik GmbH\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/zbt.de\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Hy-Lab \u2013 Laboratory for hydrogen quality - Zentrum f\u00fcr BrennstoffzellenTechnik GmbH","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zbt.de\/en\/institute\/facilities\/hy-lab-laboratory-for-hydrogen-quality\/","og_locale":"en_GB","og_type":"article","og_title":"Hy-Lab \u2013 Laboratory for hydrogen quality - Zentrum f\u00fcr BrennstoffzellenTechnik GmbH","og_url":"https:\/\/zbt.de\/en\/institute\/facilities\/hy-lab-laboratory-for-hydrogen-quality\/","og_site_name":"Zentrum f\u00fcr BrennstoffzellenTechnik GmbH","article_modified_time":"2026-10-01T13:24:29+00:00","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/zbt.de\/en\/institute\/facilities\/hy-lab-laboratory-for-hydrogen-quality\/","url":"https:\/\/zbt.de\/en\/institute\/facilities\/hy-lab-laboratory-for-hydrogen-quality\/","name":"Hy-Lab \u2013 Laboratory for hydrogen quality - Zentrum f\u00fcr BrennstoffzellenTechnik GmbH","isPartOf":{"@id":"https:\/\/zbt.de\/#website"},"datePublished":"2024-10-11T13:22:22+00:00","dateModified":"2026-10-01T13:24:29+00:00","breadcrumb":{"@id":"https:\/\/zbt.de\/en\/institute\/facilities\/hy-lab-laboratory-for-hydrogen-quality\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zbt.de\/en\/institute\/facilities\/hy-lab-laboratory-for-hydrogen-quality\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/zbt.de\/en\/institute\/facilities\/hy-lab-laboratory-for-hydrogen-quality\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zbt.de\/en\/"},{"@type":"ListItem","position":2,"name":"Institute","item":"https:\/\/zbt.de\/en\/institute\/"},{"@type":"ListItem","position":3,"name":"Equipment","item":"https:\/\/zbt.de\/en\/institute\/facilities\/"},{"@type":"ListItem","position":4,"name":"Hy-Lab \u2013 Laboratory for hydrogen quality"}]},{"@type":"WebSite","@id":"https:\/\/zbt.de\/#website","url":"https:\/\/zbt.de\/","name":"Zentrum f\u00fcr BrennstoffzellenTechnik GmbH","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zbt.de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"}]}},"_links":{"self":[{"href":"https:\/\/zbt.de\/en\/wp-json\/wp\/v2\/pages\/11289","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zbt.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/zbt.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/zbt.de\/en\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/zbt.de\/en\/wp-json\/wp\/v2\/comments?post=11289"}],"version-history":[{"count":4,"href":"https:\/\/zbt.de\/en\/wp-json\/wp\/v2\/pages\/11289\/revisions"}],"predecessor-version":[{"id":17255,"href":"https:\/\/zbt.de\/en\/wp-json\/wp\/v2\/pages\/11289\/revisions\/17255"}],"up":[{"embeddable":true,"href":"https:\/\/zbt.de\/en\/wp-json\/wp\/v2\/pages\/10562"}],"wp:attachment":[{"href":"https:\/\/zbt.de\/en\/wp-json\/wp\/v2\/media?parent=11289"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}